Mobile and stationary conditioning units
Stationary oil supply
- Tailored module for stationary application (wall mounted),
 - Numeric control of pressure/flow-rate/temperature,
 - Integrated oil reservoir with bi-cyclone defoamer,
 - Optional: specific modifications for race-car engines,
 - System for fast oil changes, level indicator,
 - safety system to prevent over-filling,
 - Temperature control: +30 … +150 °C, ± 1 K,
 - Rated power for heating/cooling: 12/150 kW,
 - Pressure control: 0 … 12 bar (relative), ± 10 mbar,
 - Flow-rate: max. 120 l × min-1,
 - Set-point transmitter: digital via CAN-Bus/PROFIBUS DP from remote panel/PC-based control system,
 - Dimension: 1.4 × 1.5 × 1.0 m (L × W × H),
 - Weight: 220 kg.
 
Mobile oil supply
- Tailored module for mobile application,
 - Numeric control for pressure/flow-rate/temperature,
 - System for fast oil changes, level indicator, safety system to prevent over-filling,
 - Temperature control: +30 … +150 °C, ± 1 K,
 - Rated power for heating/cooling : 18/200 kW,
 - Pressure control: 0 … 12 bar (relative ), ± 10 mbar,
 - Flow-rate: max. 200 l × min-1,
 - Set-point transmitter: digital via CAN-Bus/PROFIBUS DP from remote panel/PC-based control system,
 - Optional: integrated oil reservoir with cyclone defoamer,
 - Optional: specific modifications for race-car engines,
 - Dimension: 1.4 × 1.0 × 2.0 m ( L × W × H),
 - Weight: 250 kg.
 
Mobile coolant supply
- Tailored module for mobile application,
 - Numeric control of pressure/flow-rate/temperature,
 - Temperature control: +30 … +120 °C, ± 1 K,
 - Rated power for heating/cooling : 25/200 kW,
 - Pressure control: 0 … 3 bar (relative), ± 10 mbar,
 - Flow-rate: max. 400 l × min-1,
 - Water inlet/outlet: DIN-flanges 2“, DIN2632 PN16,
 - Automatic air vent, level indicator, safety system,
 - Set-point transmitter: digital via CAN-Bus/PROFIBUS DP from remote panel/PC-based control system,
 - Modular frame/building kit system,
 - Removable coverings with acoustic insulation,
 - Dimension: 1.4 × 1.0 × 2.0 m (L × W × H),
 - Weight: 250 kg.
 
Stationary coolant supply
- Tailored module for stationary application (wall mounted),
 - Numeric control of pressure/flow-rate/temperature,
 - Temperature control: +30 … +120 °C, ± 1 K,
 - Rated power for heating/cooling: 12/150 kW,
 - Pressure control: 0 … 3 bar (relative), ± 10 mbar,
 - Flow-rate: max. 180 l × min-1,
 - Water inlet/outlet: DIN-flanges 1 1/2“, DIN2632 PN16,
 - Automatic air vent, level indicator, safety system,
 - Set-point transmitter: digital via CAN-Bus/PROFIBUS DP from remote panel/ PC-based control system,
 - Welded steel frame,
 - Removable coverings with acoustic insulation,
 - Dimension: 1.4 × 1.5 × 1.0 m (L × W × H),
 - Weight: 180 kg.
 
Intake air conditioning
- Tailored module for stationary application (foot mounted),
 - Particular for high sophisticated single-cylinder test objects,
 - Numeric control for pressure/temperature/humidity of intake air,
 - High precision air-flow measurement,
 - Set-point transmitter digital via CAN-Bus/PROFIBUS DP,
 - Temperature control: +30 … +90 °C, ± 1 K,
 - Pressure control: 0 … 3 bar (absolute), ± 10 mbar,
 - Humidity: 35 … 95 % r. H.,
 - Air flow: max. 260 Nm³/h,
 - Easy to service design,
 - Optional: noise damping package,
 - Dimension: 3.0 × 1.5 × 4.0 m (L × W × H),
 - Weight: 750 kg.